                          Product Details
Place of Origin: China
Brand Name: TC
Certification: UL, RoSH, REACH, CE
Model Number: UTP-41-6-4P
Payment & Shipping Terms
Minimum Order Quantity: 50 Boxes
Price: Negotiable
Packaging Details: Seaworthy Packing
Payment Terms: Western Union, T/T, L/C, MoneyGram
| Type: | Cat 6 U/UTP | Cross Spline: | PE | Insulation: | HDPE | Conductor Material: | 99.99% BC | Conductor OD: | 24 AWG | Drain Wire: | No | Rip Cord: | Yes | Standards: | GB/T 18233 (ISO/IEC 11801); GB 50311; TIA/EIA568-C.2 | 
| Type: | Cat 6 U/UTP | 
| Cross Spline: | PE | 
| Insulation: | HDPE | 
| Conductor Material: | 99.99% BC | 
| Conductor OD: | 24 AWG | 
| Drain Wire: | No | 
| Rip Cord: | Yes | 
| Standards: | GB/T 18233 (ISO/IEC 11801); GB 50311; TIA/EIA568-C.2 | 
UTP Cat 6 Cable, Anti-Rodent Cable, Anti-Rat Cat 6 Cable, Rodent Resistant Cable, 24 AWG Application
TC's UTP-41 series, indoor Cat 6 rodent resistant unshielded cabling system has test frequency up to 350MHZ, higher than other Cat 6 cables with industry standard of 250MHz.
In the meantime, it supports the latest 5G Base-T applications and Power Over Ethernet (POE/POE+).
Product Features
 
TC's Cat 6, 24 AWG, 4-pair, unshielded indoor cable adopts cross-type spline, with outer jacket in special rodent resistant material, optimized to greatly enhance technical indicators, including Attenuation and NEXT, which exceed the parameters specified in GB/T 18015.5 (IEC 61156-5) standards.
It is especially useful in some areas with a severe rat problem, where high-speed and stable cable transmission is required.
Application Standards
 
GB/T 18233 (ISO/IEC 11801); GB 50311
Technical Details
| Transmission Performance | Cat.6 | TC | |||||
| Frequency (MHz) | 4 | 31.25 | 62.5 | 100 | 200 | 250 | 350 | 
| IL Attenuation (dB/100M) | 3.2 | 9.5 | 13.7 | 17.5 | 23.1 | 27.9 | 31 | 
| Near End Crosstalk Attenuation (NEXT, dB) | 94.7 | 63.2 | 67.3 | 62.7 | 63.9 | 55.8 | 48.2 | 
| NEXT Power and PS NEXT (dB) | 78 | 63.3 | 67.4 | 61.2 | 54.3 | 52.9 | 50.9 | 
| Equal Level Far-end Crosstalk Attenuation (ACR-F, dB) | 77 | 78.9 | 84.5 | 83.8 | 84.9 | 70.5 | 60.9 | 
| ACR-F Power and PS ACR-F (dB) | 72.8 | 62.8 | 72.4 | 70.9 | 69.7 | 65.3 | 60.3 | 
| Return Loss (RL, dB) | 32.8 | 38.6 | 32.8 | 38.6 | 32.5 | 27.8 | 25.3 | 
Notes: The values reflected in the table above are typically measured, in accordance with IEC 61156-9.
| Physical Specifications | |
| Conductor Size (nominal value) | 4×2×0.53 (AWG24) | 
| Outer Diameter of Cable (nominal value) | 6.0mm | 
| Weight (305m, with package, nominal value) | 13kg | 
| Electrical Properties | |
| DC resistance (20℃ ) | 93.8Ω/km | 
| Earth Capacity | ≦ 5.6 nF/100m (@1kHz) | 
| 100MHz Characteristic Impedance | 100Ω±15Ω | 
| Mechanical Properties | |
| Anti-Extrusion Capacity | 1000N/10cm | 
| Anti-Shock Capacity | ≥ 10 times | 
| Installation Temperature Range | -0℃ ~+40℃ | 
| Working Temperature Range | -20℃ ~+75℃ | 
| Flammability (Rodent Resistant LSZH) | |
| Flame Resistance (of single wire) | GB/T 18380.12 (IEC 60332-1-2) | 
| Smoke Density | GB/T 17651 (IEC 61034-1/-2) | 
| Hazardous Halogen Gas | GB/T 17650.1/.2 (IEC 60754-1/-2) |