Home > products > Micro Modular Data Center > Modular Data Center UPS Rack Mounted UPS 3KVA

Modular Data Center UPS Rack Mounted UPS 3KVA

Product Details

Place of Origin: China

Brand Name: TC

Model Number: TCHR1103S

Payment & Shipping Terms

Get Best Price
Highlight:

SNMP Micro Modular Data Center

,

3kVA Micro Modular Data Center

,

SNMP Rack Mounted UPS

Range Of Power:
3 To 10 KVA
Operating Methods:
1 In - 1 Out, Online Double Conversion
Input Power Factor:
≥ 0.97
Output Power Factor:
0.9
Efficiency:
90%
Input Frequency:
40-70 Hz
Output Frequency:
50/60 Hz Adaptive (adjustable)
Communication Interface:
RS232, SNMP
Range Of Power:
3 To 10 KVA
Operating Methods:
1 In - 1 Out, Online Double Conversion
Input Power Factor:
≥ 0.97
Output Power Factor:
0.9
Efficiency:
90%
Input Frequency:
40-70 Hz
Output Frequency:
50/60 Hz Adaptive (adjustable)
Communication Interface:
RS232, SNMP
Modular Data Center UPS Rack Mounted UPS 3KVA

Product Application
 

TCHR11 series Rack Mounted UPS is widely used in government, finance, communications, education, transportation, meteorology, radio and television, industrial and commercial taxation, health care, energy and electricity, and other sectors.
 

Range of Power
 

3 to 10 kVA
 

Operating Methods
 

1 in - 1 out, online double conversion
 

 

Product Features
 

It boasts a smart battery, super network management, and an adaptive system between input and output frequency. Ultra-wide input frequency (40-70Hz) is adaptive to the output frequency of 50/60Hz, designed to achieve online double conversion of all generators. Digital control technology, and ultra-high input and output power using a high-performance DSP digital processor, ensure precision, efficiency, and reliability of the data processing. The built-in battery can be replaced at runtime; in 6-10kVA, online maintenance can be performed; and it has a self-aging function.

  • Small occupation area, sharing maintenance space with cabinets;
  • Small initial investment and flexible expansion;
  • Sleep mode for power module to improve load efficiency;
  • Hot-swap power module to ensure maintenance for a working system.

 

 

Technical Details

 

Model TCHR1103S TCHR1103L TCHR1106XS TCHR1106XL TCHR1110XS TCHR1110XL
Capacity 3kVA 3kVA 6kVA 6kVA 10kVA 10kVA
Input Range of Voltage 110~288VAC (220/230/240VAC)
Frequency 40-70Hz
Power Factor ≥0.97 ≥0.99
Output Range of Voltage 220VAC±1%
Frequency 50/60Hz adaptive (adjustable)
Waveform Sine wave
Power factor 0.9 1
Overload Capacity (Invert Mode) 105% to 130% transfer to bypass after one minute;
150% transfer to bypass after 30 seconds
110% transfer to bypass after 10 minutes;
130% transfer to bypass after one minute;
150% transfer to bypass after 30 seconds, shutting down for one minute
Peak Ratio 3:01
Efficiency Main mode 90%;
ECO mode 97%
Main mode 95%;
ECO mode 98%
Battery Model 12VDC/7Ah Dependant on external batteries 12VDC/7Ah Dependant on external batteries 12VDC/9Ah Dependant on external batteries
Quantity 8 16-20 cells (optional) 16-20 cells (optional)
Maximum Charging Current 1A 4A/8A 1A 5A 1A 5A
Direct Current 96VDC 192-288VDC
Communication Interface RS232, SNMP
Options Swappable BD9 dry contact cards, B-type USB, SNMP cards, RS485 ports Swappable dry contact cards, ECO mode, corporate cards, battery packs, as well as USB, SNMP and RS485 ports
Maintenance Bypass / Standard
Environment Temperature 0-40℃
Humidity 0-95℃
Size W*D*H (mm) 440*480*173 (4U) 440*480*86 (2U) 440*660*172 440*550*86 440*660*172 440*550*86
Weight (kg) 31 9.5 58 16 62 18