Product Details
Place of Origin: China
Brand Name: TC
Certification: UL, RoSH, REACH, CE
Model Number: S/FTP-11-7A-4P-V1
Payment & Shipping Terms
Minimum Order Quantity: 50 Boxes
Price: Negotiable
Packaging Details: Seaworthy Packing
Payment Terms: Western Union, T/T, L/C, MoneyGram
Type: |
Cat 7a S/FTP |
Conductor Material: |
99.99% BC |
Conductor OD: |
23 AWG |
Length: |
305 M/box |
Braid Shield: |
Tinned Copper |
Insulation: |
HDPE |
PVC Flame Resistance: |
GB/T 18380.12 (IEC 60332-1-2) |
Fire Rating CM/CMR: |
UL 1581/ UL 1666 |
Type: |
Cat 7a S/FTP |
Conductor Material: |
99.99% BC |
Conductor OD: |
23 AWG |
Length: |
305 M/box |
Braid Shield: |
Tinned Copper |
Insulation: |
HDPE |
PVC Flame Resistance: |
GB/T 18380.12 (IEC 60332-1-2) |
Fire Rating CM/CMR: |
UL 1581/ UL 1666 |
Cat 7A Cable, Cat 7A Network Cable, CAT 7A Ethernet Cable Application
Cat 7A, the dual shielded (S/FTP) network cable with 4 pairs, supports 1000MHz of bandwidth, 25G Base-T at more than 30 m (tentatively) and 10G Base-T at 100 m, especially useful for connecting servers, switches, patch panels, and other devices in the data center, as well as high-bandwidth structured cabling systems in smart buildings.
It provides highly confidential transmission in high speed network applications, helps unify the cabling platform of current network applications, and also supports future new applications as well as Power Over Ethernet (POE/POE+) applications, so that all kinds of information from e-mail to multimedia video can be transmitted in the same set of high-speed system.
Product Features
Cat 7A, 8-core S/FTP shielded cable, uses pair shield and overall shield structure, with a separate aluminum foil shield for each pair and an overall tinned copper mesh braided shield.
This optimizes Near End Crosstalk/Far End Crosstalk (NEXT/FEXT) and Alien Near End Crosstalk (ANEXT) performance, thus resulting in a maximum transmission frequency of 1000MHz.
TC's Cat 7A shielded indoor cable is fitting and exceeding the international standards, suitable for high-speed network applications.
Application Standards
GB/T 18233 (ISO/IEC 11801); GB 50311; TIA/EIA568-C.2
Technical Details
Transmission Performance | CATV | Cat.7A | TC | ||||
Frequency (MHz) | 4 | 100 | 250 | 600 | 862 | 1000 | 1200 |
IL Attenuation (dB/100M) | 3.7 | 10.2 | 14.5 | 30.6 | 47.1 | 57.2 | 61.2 |
Near End Crosstalk Attenuation (NEXT, dB) | 95 | 125.2 | 110.7 | 108.4 | 101.3 | 122.9 | 105.1 |
NEXT Power and PS NEXT (dB) | 75 | 75 | 75 | 65.2 | 60.7 | 57.4 | 52.2 |
Equal Level Far-end Crosstalk Attenuation (ACR-F, dB) | 78 | 65.4 | 59.4 | 45.8 | 39.7 | 35.3 | 30.2 |
ACR-F Power and PS ACR-F (dB) | 75 | 62.4 | 56.4 | 42.8 | 36.7 | 32.3 | 29.3 |
Return Loss (RL, dB) | 23 | 23.6 | 21.5 | 17.3 | 17.3 | 15.1 | 12.2 |
Notes: The values reflected in the table above are typically measured, in accordance with IEC 61156-9.
Physical Specifications | |
Conductor Size (nominal value) | 4×2×0.60 (AWG23) |
Outer Diameter of Cable (nominal value) |
7.8mm |
Weight (305m, with package, nominal value) |
19.2kg |
Electrical Properties | |
DC resistance (20℃ ) |
93.8Ω/km
|
Earth Capacity | ≦ 5.6 nF/100m (@1kHz) |
100MHz Characteristic Impedance |
100Ω±35Ω
|
Transverse Conversion Loss (TCL) |
≥ 55dB-20×lgf (100-2000MHz)
|
Delay Skew | 25ns/100m |
NVP |
74%
|
Power Over Ethernet (POE) | Enhanced Power Over Ethernet under IEEE 802.3at |
Mechanical Properties | |
Minimum Bend Radius (dynamic) |
31mm
|
Minimum Bend Radius (static) |
62mm
|
Maximum Installation Tension | 100N |
Anti-Extrusion Capacity | 1000N/10cm |
Anti-Shock Capacity | ≥ 10 times |
Installation Temperature Range | -0℃ ~+40℃ |
Working Temperature Range | -20℃ ~+75℃ |
Flammability (PVC) | |
PVC Flame Resistance |
GB/T 18380.12 (IEC 60332-1-2)
|
Fire Rating CM |
UL 1581/ UL 1666
|
Flammability (LSZH) | |
Flame Resistance (of single wire) | GB/T 18380.12 (IEC 60332-1-2) |
Flame Resistance (of bunched wires) | GB/T 18380.35 (IEC 60332-3-24) |
Smoke Density | GB/T 17651 (IEC 61034-1/-2) |
Hazardous Halogen Gas | GB/T 17650.1/.2 (IEC 60754-1/-2) |