Product Details
Place of Origin: China
Brand Name: TC
Certification: UL, RoSH, REACH, CE
Model Number: UTP-11-6-4PA
Payment & Shipping Terms
Minimum Order Quantity: 50 Boxes
Price: Negotiable
Packaging Details: Seaworthy Packing
Payment Terms: Western Union, T/T, L/C, MoneyGram
Type: |
Cat 6 U/UTP |
Jacket: |
PVC |
Insulation: |
HDPE |
Conductor Material: |
99.99% BC |
Conductor OD: |
23 AWG |
Drain Wire: |
No |
Rip Cord: |
Yes |
Standards: |
GB/T 18233 (ISO/IEC 11801); GB 50311; TIA/EIA568-C.2 |
Type: |
Cat 6 U/UTP |
Jacket: |
PVC |
Insulation: |
HDPE |
Conductor Material: |
99.99% BC |
Conductor OD: |
23 AWG |
Drain Wire: |
No |
Rip Cord: |
Yes |
Standards: |
GB/T 18233 (ISO/IEC 11801); GB 50311; TIA/EIA568-C.2 |
Cat 6 Cable, Indoor Cat 6 Cable, Cat 6 Network Cable, Cat 6 Ethernet Cable, UTP Cat 6 Cable Application
It can be applied in horizontal cabling, as the portion of a telecommunications cabling system that extends from the work area telecommunications outlet to the patch panels in the distribution room, and in residential cabling that extends from the user telecommunications outlet to the patch panels.
Product Features
TC's Cat 6, 23 AWG, unshielded indoor cable adopts the excellent cross-type spline, optimized to greatly enhance technical indicators, including Attenuation and NEXT, which exceed the parameters specified in GB/T 18015.5 (IEC 61156-5) standards and ensure high-speed and stable cable transmission.
At the same time, it acts on the requirements for high transmission in data center, and structured cabling in new buildings.
Application Standards
TIA/EIA568-C.2
Technical Details
Transmission Performance | Cat.6 | TC | |||||
Frequency (MHz) | 4 | 31.25 | 62.5 | 100 | 200 | 250 | 350 |
IL Attenuation (dB/100M) | 3.2 | 10.5 | 14.7 | 20.5 | 28.5 | 32.9 | 41 |
Near End Crosstalk Attenuation (NEXT, dB) | 86.7 | 70 | 67.3 | 67.7 | 55.9 | 59.8 | 55.2 |
NEXT Power and PS NEXT (dB) | 78 | 63.3 | 57.4 | 61.2 | 54.3 | 51.9 | 46.9 |
Equal Level Far-end Crosstalk Attenuation (ACR-F, dB) | 77 | 78.9 | 84.5 | 83.8 | 84.9 | 62.9 | 60 |
ACR-F Power and PS ACR-F (dB) | 72.8 | 62.8 | 72.4 | 70.9 | 69.7 | 62.3 | 58.9 |
Return Loss (RL, dB) | 32.8 | 38.6 | 32.8 | 38.6 | 32.5 | 26.3 | 22.5 |
Notes: The values reflected in the table above are typically measured, in accordance with IEC 61156-9.
Physical Specifications | |
Conductor Size (nominal value) |
4×2×0.55 (AWG23)
|
Outer Diameter of Cable (nominal value) |
6.0mm
|
Weight (305m, with package, nominal value) |
13kg
|
Electrical Properties | |
DC resistance (20℃ ) |
93.8Ω/km
|
Earth Capacity | ≦ 5.6 nF/100m (@1kHz) |
100MHz Characteristic Impedance |
100Ω±15Ω
|
Transverse Conversion Loss (TCL) |
≥ 55dB-20×lgf (100-2000MHz)
|
Mechanical Properties | |
Minimum Bend Radius (dynamic) |
24mm
|
Minimum Bend Radius (static) |
48mm
|
Maximum Installation Tension |
100N
|
Anti-Extrusion Capacity | 1000N/10cm |
Flammability (PVC) | |
PVC Flame Resistance | GB/T 18380.12 (IEC 60332-1-2) |
Fire Rating CM | UL 1581 |