Product Details
Place of Origin: China
Brand Name: TC
Certification: UL, RoSH, REACH, CE
Model Number: FTP-11-6A-4P-V1
Payment & Shipping Terms
Minimum Order Quantity: 50 Boxes
Price: Negotiable
Packaging Details: Seaworthy Packing
Payment Terms: Western Union, T/T, L/C, MoneyGram
Type: |
Cat 6A F/UTP |
Conductor Material: |
99.99% BC |
Conductor OD: |
23 AWG |
Jacket Material: |
PVC |
Drain Wire: |
Yes |
Cross Spline: |
PE |
Insulation: |
HDPE |
Rip Cord: |
Yes |
Type: |
Cat 6A F/UTP |
Conductor Material: |
99.99% BC |
Conductor OD: |
23 AWG |
Jacket Material: |
PVC |
Drain Wire: |
Yes |
Cross Spline: |
PE |
Insulation: |
HDPE |
Rip Cord: |
Yes |
Cat 6A Cable, CAT6A Network Cable, FTP CAT6A Cable, CAT 6A Ethernet Cable Application
It can be applied in horizontal cabling, as the portion of a telecommunications cabling system that extends from the work area telecommunications outlet to the patch panels in the distribution room, and in residential cabling that extends from the user telecommunications outlet to the patch panels.
Product Features
TC's Cat 6A, 23 AWG, 4-pair, U/FTP shielded indoor cable adopts cross-type spline and overall aluminum foil shield, optimized to greatly enhance technical indicators, including Attenuation, NEXT, and ANEXT, which exceed the parameters specified in GB/T 18015.5 (IEC 61156-5) standards.
It is especially useful in some harsh electromagnetic environments where high-speed and stable cable transmission is required.
At the same time, it acts on the requirements for high transmission in data center, and structured structured cabling in new buildings.
Application Standards
TIA/EIA568-C.2
Technical Details
Transmission Performance | Cat.6A | TC | |||||
Frequency (MHz) | 4 | 31.25 | 62.5 | 100 | 300 | 500 | 600 |
IL Attenuation (dB/100M) | 3.5 | 10.1 | 14.4 | 18.2 | 28 | 35.4 | 41.4 |
Near End Crosstalk Attenuation (NEXT, dB) | 100.1 | 88.7 | 83 | 80.1 | 70.4 | 59.6 | 58.6 |
NEXT Power and PS NEXT (dB) | 90.4 | 87.1 | 80.4 | 78.6 | 68.9 | 57.8 | 56.2 |
Equal Level Far-end Crosstalk Attenuation (ACR-F, dB) | 95.8 | 91.5 | 87 | 84.1 | 76.4 | 71.6 | 72.6 |
ACR-F Power and PS ACR-F (dB) | 91.4 | 88.1 | 85.4 | 86.3 | 76.9 | 69.1 | 67.9 |
Return Loss (RL, dB) | 40.9 | 41.3 | 37.9 | 35 | 30.7 | 22.7 | 19.7 |
Notes: The values reflected in the table above are typically measured, in accordance with IEC 61156-9.
Physical Specifications | |
Conductor Size (nominal value) |
4×2×0.57 (AWG23)
|
Outer Diameter of Cable (nominal value) |
7.3mm
|
Weight (305m, with package, nominal value) |
18kg
|
Electrical Properties | |
DC resistance (20℃ ) |
93.8Ω/km
|
Earth Capacity | ≦ 5.6 nF/100m (@1kHz) |
100MHz Characteristic Impedance |
100Ω±15Ω
|
Mechanical Properties | |
Minimum Bend Radius (dynamic) |
29mm
|
Minimum Bend Radius (static) |
58mm
|
Maximum Installation Tension |
100N
|
Anti-Extrusion Capacity | 1000N/10cm |
Flammability (LSZH) | |
Flame Resistance (of single wire) | GB/T 18380.12 (IEC 60332-1-2) |
Flame Resistance (of bunched wires) | GB/T 18380.35 (IEC 60332-3-24) |
Smoke Density | GB/T 17651 (IEC 61034-1/-2) |
Hazardous Halogen Gas | GB/T 17650.1/.2 (IEC 60754-1/-2) |