Home > products > Bulk Network Cable > FTP 23AWG Ethernet CAT 6A Cable Solid Bare Copper PVC Jacket

FTP 23AWG Ethernet CAT 6A Cable Solid Bare Copper PVC Jacket

Product Details

Place of Origin: China

Brand Name: TC

Certification: UL, RoSH, REACH, CE

Model Number: FTP-11-6A-4P-V1

Payment & Shipping Terms

Minimum Order Quantity: 50 Boxes

Price: Negotiable

Packaging Details: Seaworthy Packing

Payment Terms: Western Union, T/T, L/C, MoneyGram

Get Best Price
Highlight:

Ethernet CAT 6A Cable

,

Solid Bare Copper CAT 6A Cable

,

PVC Jacket Ethernet Cable 23AWG

Type:
Cat 6A F/UTP
Conductor Material:
99.99% BC
Conductor OD:
23 AWG
Jacket Material:
PVC
Drain Wire:
Yes
Cross Spline:
PE
Insulation:
HDPE
Rip Cord:
Yes
Type:
Cat 6A F/UTP
Conductor Material:
99.99% BC
Conductor OD:
23 AWG
Jacket Material:
PVC
Drain Wire:
Yes
Cross Spline:
PE
Insulation:
HDPE
Rip Cord:
Yes
FTP 23AWG Ethernet CAT 6A Cable Solid Bare Copper PVC Jacket

Cat 6A Cable, CAT6A Network Cable, FTP CAT6A Cable, CAT 6A Ethernet Cable Application


It can be applied in horizontal cabling, as the portion of a telecommunications cabling system that extends from the work area telecommunications outlet to the patch panels in the distribution room, and in residential cabling that extends from the user telecommunications outlet to the patch panels.

 

Product Features


TC's Cat 6A, 23 AWG, 4-pair, U/FTP shielded indoor cable adopts cross-type spline and overall aluminum foil shield, optimized to greatly enhance technical indicators, including Attenuation, NEXT, and ANEXT, which exceed the parameters specified in GB/T 18015.5 (IEC 61156-5) standards.

 

It is especially useful in some harsh electromagnetic environments where high-speed and stable cable transmission is required.

 

At the same time, it acts on the requirements for high transmission in data center, and structured structured cabling in new buildings.
 

 

Application Standards


TIA/EIA568-C.2

 

 

Technical Details

 

  Transmission Performance Cat.6A TC
Frequency (MHz) 4 31.25 62.5 100 300 500 600
IL Attenuation (dB/100M) 3.5 10.1 14.4 18.2 28 35.4 41.4
Near End Crosstalk Attenuation (NEXT, dB) 100.1 88.7 83 80.1 70.4 59.6 58.6
NEXT Power and PS NEXT (dB) 90.4 87.1 80.4 78.6 68.9 57.8 56.2
Equal Level Far-end Crosstalk Attenuation (ACR-F, dB) 95.8 91.5 87 84.1 76.4 71.6 72.6
ACR-F Power and PS ACR-F (dB) 91.4 88.1 85.4 86.3 76.9 69.1 67.9
Return Loss (RL, dB) 40.9 41.3 37.9 35 30.7 22.7 19.7


Notes: The values reflected in the table above are typically measured, in accordance with IEC 61156-9.

 
 
  Physical Specifications
Conductor Size (nominal value)
4×2×0.57 (AWG23)
Outer Diameter of Cable (nominal
value)
7.3mm
Weight (305m, with package,
nominal value)
18kg

 

 

  Electrical Properties
DC resistance (20℃ )
93.8Ω/km
Earth Capacity ≦ 5.6 nF/100m (@1kHz)
100MHz Characteristic Impedance
100Ω±15Ω

 

 

  Mechanical Properties
Minimum Bend Radius (dynamic)
29mm
Minimum Bend Radius (static)
58mm
Maximum Installation Tension
100N
Anti-Extrusion Capacity 1000N/10cm

 

 

  Flammability (LSZH)
Flame Resistance (of single wire) GB/T 18380.12 (IEC 60332-1-2)
Flame Resistance (of bunched wires) GB/T 18380.35 (IEC 60332-3-24)
Smoke Density GB/T 17651 (IEC 61034-1/-2)
Hazardous Halogen Gas GB/T 17650.1/.2 (IEC 60754-1/-2)