Product Details
Place of Origin: China
Brand Name: TC
Certification: UL, RoSH, REACH, CE
Model Number: GJFJU-xx
Payment & Shipping Terms
Application: |
Indoor/Outdoor |
Fiber Type: |
Single Mode/Multimode |
Fiber No.: |
2-12 |
Jacket Material: |
TPU |
Min. Bend Radius: |
16 Mm |
Jacket Thickness: |
1.0±0.1 Mm |
Jacket Color: |
Black |
Standard: |
YD/T 1258.3-2009; YD/T 1258.4-2005; GB/T 13993.3-2014 |
Application: |
Indoor/Outdoor |
Fiber Type: |
Single Mode/Multimode |
Fiber No.: |
2-12 |
Jacket Material: |
TPU |
Min. Bend Radius: |
16 Mm |
Jacket Thickness: |
1.0±0.1 Mm |
Jacket Color: |
Black |
Standard: |
YD/T 1258.3-2009; YD/T 1258.4-2005; GB/T 13993.3-2014 |
Indoor/Outdoor Tactical Fiber Optic Cable Application
Indoor/Outdoor tactical fiber optic cable is mainly used for indoor and tactical cabling, for connections among telecommunication rooms, between equipment rooms and instrument rooms, as well as among instrument rooms.
The cable is constructed of several φ900μm (singlemode or multimode) tight buffered fibers surrounded by aramid yarn strength members jacketed in a TPU outer jacket. Its non metallic strength member provides lightning protection.
Product Features
Application Standards
YD/T 1258.3-2009; YD/T 1258.4-2005; GB/T 13993.3-2014
Color Code |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Blue | Orange | Green | Brown | Slate | White | Red | Black | Yellow | Violet | Rose | Aqua |
Flame resistance |
Flammability standard for single wire: | GB/T 18380.12- 2008 |
Flammability standard for bunched wires: | GB/T 18380.35- 2008 |
Jacket: Peel off 50mm-long cable, place the empty jacket horizontally and burn for 4-5 seconds, using alcohol lamp; after the fire source is taken away, it extinguishes less than 2 seconds;
|
Technical Details
Optical Properties | ||||||
Type of Optical Fiber |
Attenuation | Injection Bandwidth (OFL) |
Effective Modal Bandwidth |
10 Ethernet Link Length SX |
Min. Bend Radius (mm) |
|
850nm/1300nm | 850/1300nm | 850nm | 850nm | |||
Typical Value (dB/km) | Max. Value (dB/km) | MHz·km | MHz·km | |||
MM62.5/125 OM1 | 3.0/1.0 | 3.5/1.5 | ≥ 200/500 | / | / | 30 |
MM50/125 OM2 | 3.0/1.0 | 3.5/1.5 | ≥ 500/500 | / | ≥ 150 | 30 |
MM50/125 OM3 | 3.0/1.0 | 3.5/1.5 | ≥ 1500/500 | ≥ 2000 | ≥ 300 | 30 |
MM50/125 OM4 | 3.0/1.0 | 3.5/1.5 | ≥ 3500/500 | ≥ 4700 | ≥ 550 | 30 |
Mechanical Properties | |||||||||
Type of Fiber Optic Cable | Diameter (mm) | Weight (kg/km) | Tensile Strength (N) | Crush Resistance (N/100mm) | Bend Radius | Jacket Thickness (mm) | |||
Long Term | Short Term | Long Term | Short Term | Dynamic | Static | ||||
GJFJU-2 core | 6.0±0.3 | 30 | 500 | 1500 | 1000 | 5000 | 20D | 10D | 1.0±0.1 |
GJFJU-4 core | 6.0±0.3 | 30 | 500 | 1500 | 1000 | 5000 | 20D | 10D | 1.0±0.1 |
GJFJU-6 core | 6.6±0.3 | 35 | 500 | 1500 | 1000 | 5000 | 20D | 10D | 1.0±0.1 |
Jacket Specifications | |||
Type of Optical Fiber | Color | Surface | Material |
A1b | Black | Bright color, no sand, raw skin or scratch on the surface | TPU |
A1a | Black | Bright color, no sand, raw skin or scratch on the surface | TPU |
A1a OM3 | Black | Bright color, no sand, raw skin or scratch on the surface | TPU |
A1a OM4 | Black | Bright color, no sand, raw skin or scratch on the surface | TPU |